    非上门服务

    • All-round check-up of service device with check list
    • Temporary replacement logger to assure a complete chain of data record
    • Electrical, manufactory and SCS calibration service with certificate
    • Clear warranty approach and customer friendly accommodation solutions

    Designed to fit your expectations
    ELPROs Off-Site Service includes maintenance, repair and calibration of mobile data loggers and accessories at ELPRO’s certified laboratory. Send us your monitoring equipment to prolong the service life of your investment and keep on track with your core business. This service is offered in addition to ELPRO’s On-Site Service where an ELPRO technician installs, calibrates and maintains installations and equipment at the customer site.

     

    Service Offer

    Off-Site Service for Data Loggers
    The following data loggers can be sent to ELPRO for Off-Site service:

    • ECOLOG
    • ECOLOG-NET
    • HAMSTER (Type ET1/D, ET2, EHT1, AT1)
    • HOTDOG DT1 and HOTBOX (HTN, HTH, SE)
    • LIBERO (Type Tx1 and Cx)
    • Non-ELPRO branded loggers (not requiring software for calibration)

    Temporary Replacement Data Logger / Exchange Probes (Optional)
    Do you need an ongoing recording of your data during Off-Site Service of your equipment? ELPRO offers Temporary Replacement Data Loggers and Exchange Probes so you can keep monitoring while your equipment is away for Off-Site Service. Order your required Temporary Replacement Data Logger or Exchange Probes in time before sending your equipment to ELPRO for Off-Site Service. After you have your equipment back, return the temporary equipment.

    The following data loggers and probes are available as temporary replacements:

    • ECOLOG TNx, TPx, TH1
    • LIBERO Ti1/Ti1-L
    • Exchange T/RH probe

    Check-up (Regular)
    Each data logger sent to Off-Site Service will run through the Check-up process. Within Check-up ELPRO tests and verifies the functionality of your device. Optical inspection includes checking and cleaning of housing, existing interfaces / sockets (DB15, Lemo, rH, USB) and battery case. If foreseen for your device, ELPRO will exchange the battery, check the programming and readout functionality and update the battery exchange date. The age of the data logger will be determined and if available also the display and keyboard functionality are checked. External channels, internal probes and other accessories like brackets, external probes or data cables will go through electrical inspection. During the Check-up no calibration certificate is issued. Should you require a calibration certificate, please order the Calibration service for your device.

     

    Data Recovery (Optional)
    In addition to Check-up, ELPRO offers a Data Recovery service which can be ordered separately. Data Recovery can involve specialist methods to read out existing data on the customer's data logger. If data can be recovered, an interpretation of the data is performed (what kind of data has been read out, are date and time stamps plausible, what data is trustworthy and from when on data might not be reliable anymore). In case of successful Data Recovery the customer receives the recovered data in electronic format.

    Repair (Optional)
    Repair service takes care of your data logger should something happen to it. Repaired data loggers or accessories benefit from a six months waranty. ELPRO offers the following Repair services:

    • For ECOLOG, types TN2, TN3-P, TN4, TN4-L, TH1, TH2, TP2 and TP4-L: Repair of display, keyboard, quartz (clock), rH socket and Lemo socket.
    • For external probes: Replacement of connector and shorten cable in case of damaged cable or connector. The repair is concluded with an ice water test.

    Calibration (Optional)
    During Calibration service, the measurement of a test object is compared with a traceable reference. The accuracy is documented and confirmed in a calibration certificate. ELPRO’s laboratories are certified for various measuring parameters and accredited to highest national standards (NIST, UKAS, SCS, etc.). ELPRO offers various standard and customized Calibration services. Those services differ in the process, the number and settings of calibration points and in the level of detail of the certificates. An excerpt of the calibration offering can be seen in the table on page 4.

    Warranty and 8D Report (Optional)
    A clarification regarding Warranty and 8D Report (damage report) is available optionally. For all clarifications first the Check-up process is completed. In case that the equipment is under warranty, ELPRO does not charge for Check-up and will repair or replace the equipment free of charge. In other cases, ELPRO offers refunds or discounts for new devices, depending on age and general condition of your equipment.

    Recycling
    Data loggers which cannot be used or repaired, will be professionally recycled. ELPRO believes in respecting our environment today and for future generations. Alternatively, we can send non-repairable equipment back to the customer.

    如果你想要更详细资料,请通过 sales@dgruijun.com 联系我们。 E-mail本页 Email该网页
     
    我们为您证明 - 创新的易腐品供应链全过程环境条件监测 LIBERO PDF记录仪目录 瑞士设计开发
    应用行业
    制药和实验室
    药品运输物流和分销
    医疗保健
    生物样本库和生命科学
    食品
    环境条件
    解决方案
    产品运输监测解决方案
    室内和设备监测解决方案
    独立监测解决方案
    容器监测系统
    测试和验证系统
    服务
    产品系列
    数据记录仪
    传感器和变送器
    支架
    报警器
    软件
    服务
    其它品牌数据记录仪
    温度、湿度、压力变送器和调节器
    数据记录仪
    监测系统
    可打印温度记录仪
    手持温湿度压力计

    加关注


    关于虹科
    :
    虹科积极进取,不断探索科技新领域。最优秀的员工和最好的技术能够接受最困难的挑战。为您找到最佳解决方案。虹科靠口碑赢得客户。

    Email 新浪微博 论坛 点击发送消息给我

    北京:010-5781 5040 | 上海:021-6728 2707 | 西安:029-8187 3816 | 广州:400 999 3848 | 成都 028-6138 2617
    台湾 901299121 | 香港 6749 9159

    sales@dgruijun.com | 广州虹科电子科技有限公司 | 版权所有 | 广州科学城润慧科技园C栋6层

    友情链接: